Embed Square Solutions

Standards

The standard is the starting brief

Every design starts from the applicable standard, not from a reference design.

CISPR 25ISO 11452-2ISO 7637-2ISO 16750-2

Automotive, EMC, environmental, safety and defence

Automotive — emission
CISPR 25
Component-level conducted and radiated emission, 150 kHz – 2.5 GHz
Automotive — immunity
ISO 11452-2ISO 7637-2ISO 16750-2ISO/TR 10605
ALSE radiated immunity · conducted switching transients · electrical loads on 12 / 24 V nets · ESD for road vehicles
EMC — immunity
IEC 61000-6-2-4-2-4-3-4-4-4-5-4-6-4-11
Generic industrial immunity, ESD, radiated RF, EFT, surge, conducted RF, dips
EMC — emission
IEC 61000-6-4CISPR 11 Class A
Generic industrial and ISM emission limits
Environmental
IEC 60068-2-1-2-2-2-6-2-27-2-30-2-78
Cold, dry heat, vibration, shock, damp heat
Safety
IEC 61010-1IEC 61131-2
Measurement, control and laboratory equipment; programmable controllers
Defence
MIL-STD-810G / HMIL-STD-461F / GMIL-STD-1553
Environmental, EMC and avionics data bus
EV charging
IEC 61851UL 198
AC and DC charging platforms; insulation monitoring for IT systems
Regulated data
21 CFR Part 11
Audit trails, e-signatures and access control

How a standard becomes a design input

Every design starts from the applicable standard, not from a reference design. At kickoff the standard is mapped clause by clause to design features and test evidence, so the cost of compliance is known before layout begins — not discovered at the test house.

What we test here, what we do not

Pre-compliance runs in our own lab: ESD, transient and surge injection, emissions pre-scan, RF immunity pre-checks, climatic and mechanical profiling, and long-run soak. Type approval and certification run at accredited laboratories — CISPR 25 and ISO 11452-2 measurements in particular require a chamber we do not operate, so those results are always third-party. We say which is which on every report.

Do you test CISPR 25 in-house?

We run a CISPR 25 pre-scan on our own bench. Formal CISPR 25 measurement requires an absorber-lined chamber and is carried out at an accredited laboratory.

Which ISO 7637-2 pulses can you simulate?

Pulses 1, 2a, 2b, 3a, 3b, 4 and 5, using automotive ECM test systems, including load dump and cranking profiles.

Are you an accredited laboratory?

No. We provide pre-compliance testing and evidence preparation. Certification is obtained at accredited third-party laboratories.

Tell us which standard your product has to pass